You can download the dedicated manuals for the channeling kits within the reserved area “boutique/technical assistance centers,” using the following login credentials:
- Username: moretti-design-en
- Password: boutique-cat-en
Below are the wiring and parameter configuration for the four channeling kit models: MFDCS/MFDCD, MFRA, MULTIRELAX, and MULTIGLOBE.
Models: Aladino, Elegance, Clessidra, Ergonomic, Dream (Channeling Kit Code: MFDCS/MFDCD)
Models: Compact, Slot Glass, Slot Vision (Channeling Kit Code: MFRA)
Configuration with 1 channeling
Wiring: connect the motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
06 HOT AIR POWER: set the value to OFF
07 NUMBER OF CH: set the value to 1
Configuration with 2 channelings
Wiring: connect the right motor to the AUX1 terminal and the left motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
06 HOT AIR POWER: set the value to OFF
07 NUMBER OF CH: set the value to 2
Models: Globe Glass Relax, Globe Glass Relax Plus (Channeling Kit Code: MULTIRELAX)
Configuration with 1 channeling
Wiring: connect the motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
07 NUMBER OF CH: set the value to 1
Configuration with 2 channelings
Wiring: connect the right motor to the AUX1 terminal and the left motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
07 NUMBER OF CH: set the value to 2
Models: Globe Glass Aria, Trifolium (Channeling Kit Code: MULTIGLOBE)
Configuration with 1 channeling
Wiring: connect the motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
Configuration with 2 channelings
Wiring: connect the right motor to the AUX1 terminal and the left motor to the V2/PO terminal.
Parameters: access the system menu with password M0 and modify the parameters as follows:
Channeling Data
01 ENABLE CHAN.: set the value to ONNew Management
03 Fans: set the value to ON
Comments