The Air stoves allow you to change the operating mode of the screw conveyor, choosing between regulation by seconds (SEC) or by revolutions per minute (RPM) via encoder.
To ensure stable, precise, and efficient operation of the screw conveyor, it is recommended to use the RPM mode, which ensures more accurate combustion control.
The parameter that defines the screw conveyor management mode is 01 ABIL. COCLEA CONT., section "Screw Conveyor Menu Var", in the System Menu:
- ON → operation in RPM with encoder (default setting)
In this configuration, the control unit reads the values present in "Factory Calibration," from parameter 04 to parameter 10, as well as parameter 30. - OFF → operation in SEC
In this configuration, the control unit reads the values present in "Screw Conveyor Menu Var", from parameter 02 to parameter 09.
Comments
0 comments
Please sign in to leave a comment.