The remote control PSYSI04000005 (NG21) is equipped with an ambient thermostat function, which can be activated through the following path:
SETTINGS → RADIO THERMOSTAT → ON
With this configuration active, after turning on, the stove automatically modulates the power upon reaching the set temperature.
Note: In the standard configuration, the stove does not turn off upon reaching the ambient temperature, but it may turn off/standby due to other safety features or parameters set in the control unit.
Configuration for On-Off Mode Operation
It is possible to configure the system so that the ambient thermostat of the remote control manages the complete shutdown of the stove upon reaching the set temperature.
With this configuration, the stove will operate in On-Off mode.
Parameters to set in the control unit:
- P26 = 0 (default value)
- P70 = 0 → deactivation of input IN9
- A01 = 0 → On-Off mode
- T45 = 0
After modifying the parameters:
- Save the settings.
- Verify the correct on and off cycle based on the ambient temperature set on the remote control.
Comments