When accessing the “Night Mode” menu, it is necessary to:
- Set the start time of the night mode.
- Set the end time of the night mode.
- Enable the function by selecting the checkbox in the appropriate box.
During the set time period, the loading and cleaning motors must not operate.
Technician Settings
To ensure the deactivation of the motors during the time periods indicated above, the technician must access the System menu and modify the following parameters:
- Loading Motor (auger motor)
- Parameter P100
- Default: 0 (normal operation)
- Night Mode Setting: 1 (OFF)
- Cleaning Motor (grate cleaning motor)
- Parameter P103
- Default: 0 (normal operation)
- Night Mode Setting: 1 (OFF)
- Cleaning Motor 2 (turbulator cleaning motor)
- Parameter P102
- Default: 0 (normal operation)
- Night Mode Setting: 1 (OFF)
- Cleaning Motor 3 (not used)
- Parameter P101
- Default: 0 (normal operation)
- Night Mode Setting: 1 (OFF)