Proper installation of the pressure transducer is essential to ensure the safe and efficient operation of the stove. Below are the operational instructions to follow.
Preliminary Safety Conditions
Before proceeding with any operation:
- Make sure the stove is completely turned off
- Verify that the circuit is not under pressure
- Wait for the appliance to cool down completely, if necessary
Procedure for Removing the Transducer (MFRHC505)
- Shutting Down the System
Turn the stove to OFF and disconnect it from the electrical power supply. - Pressure Release
Ensure there is no residual pressure inside the circuit. - Draining the Water
Proceed to completely drain the water contained in the stove using the designated drainage points. - Removing the Transducer
- Disconnect the electrical connector
- Unscrew the pressure transducer (model MFRHC505) from its seat
Procedure for Installing the New Transducer
- Installing the New Component
Screw the new transducer into the seat, ensuring proper sealing (use appropriate gaskets or sealants if necessary). - Electrical Connection
Reconnect the electrical connector, verifying the stability of the contact. - Circuit Restoration
- Refill the stove with water
- Restore the pressure according to the values specified by the manufacturer
- Final Check
- Check for any leaks
- Turn the stove back on and verify the correct operation of the transducer