Description:
Error ER02 occurs on products made before 2016 equipped with a 20-10 pressure switch connected to the combustion chamber. It indicates an anomaly in the management of air/smoke flow or in the ventilation control.
Checks to perform (CAT):
- Smoke fan setting check
- Verify if the smoke fan is set to Volts.
- If so, restore operation to RPM.
- If the fan is already in RPM:
- Check for any air intake from the combustion chamber
- Possible cause: seals not perfectly tight.
- Check the condition of the flue
- Possible obstruction or partial clogging.
- Check for any air intake from the combustion chamber
Operational notes:
- Ensure that all pressure switch connections are intact and properly connected.
- After intervention, perform a complete operation test.