AQUA Stoves – Moretti Design
On AQUA stoves by Moretti Design, the three-way valve can be connected to the NG21 control unit – connector A2, depending on the type of actuator installed.
Types of connections:
1. Three-way valve with spring return
NG21 control unit connection (A2):
- PIN 16 → N (Neutral)
- PIN 18 → Fon (Phase ON)
2. Three-way valve with ON phase / OFF phase
NG21 control unit connection (A2):
- PIN 16 → N (Neutral)
- PIN 17 → Foff (Phase OFF)
- PIN 18 → Fon (Phase ON)
3. Three-way valve with ON / OFF phase + fixed phase
NG21 control unit connection (A2):
- PIN 16 → N (Neutral)
- PIN 17 → Foff (Phase OFF)
- PIN 18 → Fon (Phase ON)
- PIN 19 → F (Fixed phase)
Technical notes
- Always verify the type of actuator before making connections.
- Incorrect connections may cause malfunction of the valve or the NG21 control unit.
- Operate only with the electrical power turned off.
Comments